1.17 MOLD PROOF Operation

This is an integrated naming of functions of inside drying and moisture exhaustion. Drying inside
the air conditioner prevents mold and odors from growing.
Operation
Operation can be selected from automatic and manual.
Features
Function and Control
Automatic operation
If MOLD PROOF operation is set ON, the MOLD PROOF operation starts automatically after
"SARARA" DRYING or COOLING operation. Operation starts depending on the amount of
time the unit has been run. (approximately once every 2 weeks)
Manual operation
Time chart
Operation runs about for 3 hours while changing colors of the multi-colored indicator lamp.
Cooling Stop
Indoor fan
LLL tap
OFF
Minimum open
Horizontal flap
Fully closed
Heating Min.
Compressor
OFF
Damper
Fully opened
Exhaust side
Moisture discharge fan
ON
OFF

MOLD PROOF operation

(Hold down for 2 seconds.)
Drying by
Pre-drying
heating 30 min.
10 min.
Discharge
Discharge moisture
Perfectly dry the inside by
moisture
while heating and
short circuit blowing +
drying the heat
discharge
exchanger
Start
(R13892)
Finish up drying
Thorough operation
operation 80 min.
60 min.
Lower relative humidity and
inactivate fungi by short circuit
heating + discharge
3 hours
Main Functions
Complete
(R13893)