Daikin SiBE04-624_B_FTXR-E Service Manual page 54

Wall mounted type e-series
Table of Contents

Advertisement

Main Functions
1. Drained water discharge
Drained water in the drain pan is discharged.
3. Moisture exhaustion
Moisture is exhausted to outdoors through the humidification hose.
1. Accumulated operation time: 21,600 minutes (approx.15 days)
2. Accumulated "SARARA" DRYING and COOLING operation time: 5,400 minutes (approx.15
This function starts when both conditions are met.
Note:
44
Switching air supply / exhausting
This function was realized by developing damper inside the humidifier unit.
Air supply position
Conditions for operation
days × 6 hours)
This is not the function for eliminating dust or mold attached inside the air conditioner.
During operation, smells may occur.
This function sometimes does not begin when outdoor temperature or indoor humidity is
extremely high.
Depending on the temperature conditions, moisture exhaustion function is not carried out.
2. Inside drying operation
After the drained water discharged, the moisture which
are left on the drain pan or the indoor heat exchanger
are dried by evaporation.
Exhausting position
SiBE04-624_B
(R18354)
Function and Control