Daikin SiBE04-624_B_FTXR-E Service Manual page 38

Wall mounted type e-series
Table of Contents

Advertisement

Main Functions
Performance
The maximum piping length is set to 10 m, but the humidifying capacity varies depending on the
length of the humidifying hose.
correction by
When the hose length increases by 2 m, the humidifying capacity decreases by about 10%.
hose length
Reference
28
120%
100%
80%
2
Room humidity (humidity of the discharged air) by ventilation rate
(16 m
2
, hose length: 4 m, 28 class)
1. Outdoor temp. 0°CDB, 50%RH
100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
0%
0
0.2
2. Outdoor temp. 7°CDB, 87%RH
100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
0%
0
0.2
Outdoor temp. 7˚CDB, 6˚CWB
4
6
Hose length (m)
0.4
0.6
0.8
1
Ventilation rate (times/hour)
0.4
0.6
0.8
1
Ventilation rate (times/hour)
SiBE04-624_B
8
10
(R13869)
Set temperature
17˚C
20˚C
23˚C
1.2
1.4
1.6
1.8
(R13870)
Set temperature
17˚C
20˚C
23˚C
1.2
1.4
1.6
1.8
(R13871)
Function and Control

Advertisement

Table of Contents
loading

Table of Contents