4. Field Settings

4.1

Humidifying Hose Length Setting

Outline
Set the humidifying hose length to ensure humidifying capacity. Use the remote controller to set
the humidifying hose length. Power on the unit to establish the communication between the unit
and the remote controller.
(The humidifying hose length includes the rear part of the indoor unit.)
Detail
1) Press the [CLOCK] button for 5 seconds.
2) Press the [SELECT]
3) Press the [CLOCK] button to activate the hose length setting mode.
4) Press the [SELECT]
5) Press the [CLOCK] button to set the hose length.
6) To return to the normal mode, press the [CLOCK] button for 5 seconds or leave the remote
Note:
Trial Operation and Field Settings
[SELECT]
is displayed.
or
→ The display shows the preset hose length.
When the hose length is not set,
or
You can select hose length from [~ 3 m] [3.1 ~ 4 m] [4.1 ~ 6 m] [6.1 ~ 8 m] [8.1 ~ 10 m].
controller for 60 seconds.
If you set the wrong humidifying hose length, select
setting.
When setting the humidifying hose length without powering on the indoor unit, the display
shows
on the step 5) but the remote controller remembers the set hose length.
When the customer turns the indoor unit on, the hose length information is sent to the indoor
unit.
Display
button
[CLOCK] button
button and select
is displayed.
button and select hose length.

Field Settings

(R14036)
.
on the step 4) to cancel the
149