Time chart for
Approximately 1 minute after heating operation starts, humidifying operation and drying
operation repeats alternately to prevent condensation inside the hose.
humidifying
operation control
(a): Humidifying time
(b): Drying time
(b'): Drying time
Note:
In a room that is spacious such as loft style or partitioned by an accordion style curtain, the
ventilation volume is large and sometimes may not reach the set humidity.
Function and Control
ON
Heating
OFF
operation
ON
Humidifying
fan damper
OFF
ON
Hygroscopic
OFF
fan
15 sec.
ON
Drying
Heater
OFF
ON
Humidifying
OFF
rotor
Approx. 70 min.
Approx. 2~10 min.
Approx. 2~10 min.
Humidifying trial operation has no 1-minute-delay, it immediately starts up from
works in the same sequence as normal humidifying operation.
Humidifying trial operation automatically stops after about 30 minutes.
Approx. 1 min.
(b')
(a)
(b)
(a)
According to the outdoor temperature and the
hose length set by remote controller
According to the hose length set by remote
controller
Main Functions
Approx. 3 min.
(b)
(a)
(b')
15 sec.
(R18142)
, and
(b')
25