1.9

MOISTURIZING Operation

Operation
Features
Function and Control
Effective mode for MOISTURE COOLING operation
• COOLING
• DRY COOLING
Effective mode for MOISTURE HEATING operation
• HEATING
• HUMID HEATING
MOISTURIZING operation has following 3 features.
• Relatively high humidity setting
• COMFORT AIRFLOW operation
• Emission of vitamins and hyaluronic acid
MOISTURIZING operation is not for beauty and beautiful skin treatment, nor prevention of
skin roughness.
Details of operation
<Humidity in MOISTURE COOLING operation>
MOISTURE COOLING 65%
DRY COOLING 50~60%
Rotation speed of indoor unit fan
• MOISTURE COOLING operation keeps the humidity at 65%.
• Unlike ordinary DRY COOLING, it prevents the room from drying.
<Humidity in MOISTURE HEATING operation>
MOISTURE HEATING 60%
HUMID HEATING 45~55%
Rotation speed of indoor unit fan
• MOISTURE HEATING operation keeps the humidity at 60%.
• Air is moisturized more than in ordinary HUMID HEATING.