Adjustment Types of Color Calibration
If the paper you are using does not support color calibration, execute color calibration using the paper where the
adjustment type is Common calibration, then you can set the calibration adjustment values for the paper you are
Note
using.
The calibration adjustment values are not overwritten for media types where color calibration has been executed
once and dedicated calibration adjustment values have been set.
Unique calibration
If color calibration is executed on paper categorized as Unique calibration, calibration adjustment values are
set only for the media type that the color calibration was executed on.
Even if paper categorized as Unique calibration is used, if the media type has yet to execute color calibration even
once and does not have any dedicated calibration adjustment values, the calibration adjustment values are over-
Note
written when Common calibration is executed.
Calibration values configured by color calibration using the printer sensor and calibration values configured by color
calibration using the optional Spectrophotometer Unit are managed as separate data.
Because of this, the calibration values configured using the Spectrophotometer Unit are not overwritten when Com-
mon calibration is executed using the printer sensor.
Checking the Applied Calibration Values
Depending on the paper type, it may be possible to execute color calibration using both the printer sensor and the
Spectrophotometer Unit and to have two sets of calibration values.
In this case, the calibration values that were set when color calibration was executed the last time are applied when
printing.
The currently applied calibration values can be checked using the Color Calibration Management Console or
Control Panel menu.
How to Check
738
Check in the
Color Calibra-
tion Manage-
ment Console.
How to Operate
Display the Paper Status dialog box and
view the Type.
(See "Calibration Sheet (Win-
dows).")
P.752
(See "Calibration Sheet (Mac
OS).")
P.784
Displayed Content
Auto Adjust: Calibration values set using the printer sensor
Auto Adjust (High Precision): Calibration values set using the
Spectrophotometer Unit
iPF8400S
User's Guide