Specifications - Sanremo ROMA TCS SED Instruction Booklet

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 45
ENGLISH
This manual is for use by qualified personnel and contains information and tips to use and keep your coffee maker as efficiently as possible.
Please read all instructions very carefully before you actually use your machine to make sure the machine works properly and to ensure a long
working life. Instructions are part of the product. Please keep this document. This booklet refers to the following models:
Electronic model controlled by microprocessor with dispensing programmable through special pushbutton panel with indicator lights and switch
for continual manual dispensing. Available in 2 group version.
WIDTH (X)
DEPTH (Y)
HEIGHT (Z)
BOILER CAPACITY
SMALL BOILER CAPACITY
NET WEIGHT
GROSS WEIGHT
SUPPLY VOLTAGE
POWER ABSORBED BY THE BOILER RESISTANCE
POWER ABSORBED BY THE TCS SMALL BOILER RESISTANCE
POWER ABSORBED BY CUP WARMER
POWER ABSORBED BY THE ELECTRIC PUMP
POWER ABSORBED BY THE SOLENOID VALVES
POWER ABSORBED BY THE EXTERNAL ELECTRIC PUMP
POWER ABSORBED BY THE AUTOMATIC LEVEL REGULATOR
BOILER PROJECT PRESSURE
BOILER WORKING PRESSURE
SAFETY VALVE CALIBRATION PRESSURE
HEAT EXCHANGER PROJECT PRESSURE
HEAT EXCHANGER SAFETY VALVE CALIBRATION PRESSURE
WATER MAINS PRESSURE (MAX)
COFFEE DISTRIBUTION PRESSURE
The weighted sound pressure level A of the coffee machine is less than 70dB.
For correct appliance operation and trouble-free maintenance, please read this booklet carefully and comply with the instructions and rules, also
referring to the diagrams given in it.
Before installing the appliance ensure that the mains voltage and power correspond to the data given in the
specifications table. Take the appliance out of the packaging and put it in its final place of installation ensuring that
it is stable and safe and that there is the necessary space for using it. Place the machine in a way that the distance
between the grid and the floor is wider than 1,5 mt. See photograph. To clean the internal circuit more efficiently,
you are recommended to empty and fill the boiler a number of times and deliver simple water and coffee to be
thrown away.
ROMA TCS SED
FOREWORD
Model – ROMA TCS SED

SPECIFICATIONS

INSTALLATION
45
GROUPS
2 TCS
mm
850
mm
560
mm
535
litri
8,6
litri
0,33
Kg
87
Kg
90
120
V
220 - 240 ~
380 - 415 ~
kW
2,7
kW
1
kW
0,2
kW
0,15/0,165
kW
0,15/0,165
kW
0,0225
kW
0,01
(2 Bar) MPa
0,2
(0,8-1 Bar) MPa
0,08:0,1
(1,8 Bar) MPa
0,18
(20 Bar) MPa
2
(12 Bar) MPa
1,2
(6 Bar) MPa
0,6
(8-9 Bar) MPa
0,8/0,9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents