Sanremo VERONA SAP Manual
Hide thumbs Also See for VERONA SAP:

Advertisement

ENGLISH
Width (X)
Depth (Y)
Height (Z)
Boiler capacity
Small boiler capacity
Net weight
Gross weight
Supply voltage
Power absorbed by the boiler resistance
Power absorbed by the tcs small boiler resistance
Power absorbed by cup warmer
Power absorbed by the electric pump
Power absorbed by the solenoid valves
Power absorbed by the external electric pump
Power absorbed by the automatic level regulator
Boiler project pressure
Boiler working pressure
Safety valve calibration pressure
Heat exchanger project pressure
Heat exchanger safety valve calibration
pressure
Water mains pressure (max)
Coffee distribution pressure
VERONA
FOREWORD
Model – VERONA SAP
Model – VERONA SED - SED TCS
SPECIFICATIONS
GROUPS
2 BASE
2 TCS
mm
820
820
mm
610
610
mm
590
590
litres
12
8,6
litres
/
0,28
Kg
59
60
Kg
62
63
120
120
V
220 - 240
220 - 240
380 - 415
380 - 415
kW
2,7/4,5
2,7/4,5
kW
/
kW
0,2
0,2
kW 0,15/0,165 0,15/0,165 0,15/0,165 0,15/0,165 0,15/0,165
kW 0,15/0,165 0,15/0,165 0,15/0,165 0,15/0,165 0,15/0,165
kW
0,0225
0,0225
kW
0,01
0,01
(2 Bar) MPa
0,2
0,2
(0,8-1 Bar) MPa
0,08:0,1
0,08:0,1
(1,8 Bar) MPa
0,18
0,18
(20 Bar) MPa
2
(12 Bar) MPa
1,2
1,2
(6 Bar) MPa
0,6
0,6
(8-9 Bar) MPa
0,8/0,9
0,8/0,9
This booklet refers to the following models:
X
Y
2 BASE TALL 2 TCS TALL
820
820
610
610
652
652
12
8,6
/
0,28
63
64
66
67
120
120
220 - 240
220 - 240
380 - 415
380 - 415
2,7/4,5
2,7/4,5
1
/
1
0,2
0,2
0,0225
0,0225
0,01
0,01
0,2
0,2
0,08:0,1
0,08:0,1
0,18
0,18
2
2
2
1,2
1,2
0,6
0,6
0,8/0,9
0,8/0,9
50
Z
3 BASE
3 TCS
3 BASE TALL 3TCS TALL
1050
1050
1050
610
610
610
590
590
652
19
14
19
/
0,28
/
84,5
85,5
92
89,5
90,5
99
120
120
120
220 - 240
220 - 240
220 - 240
380 - 415
380 - 415
380 - 415
5,1
5,1
5,1
/
1
/
0,25
0,25
0,25
0,165
0,15/0,165
0,187
0,15/0,165
0,0315
0,0315
0,0315
0,01
0,01
0,01
0,2
0,2
0,2
0,08:0,1
0,08:0,1
0,08:0,1
0,18
0,18
0,18
2
2
2
1,2
1,2
1,2
0,6
0,6
0,6
0,8/0,9
0,8/0,9
0,8/0,9
1050
610
652
14
0,33
92
99
120
220 - 240
380 - 415
2,7
1
0,25
0,165
0,187
0,0315
0,01
0,2
0,08:0,1
0,18
2
1,2
0,6
0,8/0,9

Advertisement

Table of Contents
loading

Summary of Contents for Sanremo VERONA SAP

  • Page 1 ENGLISH VERONA FOREWORD This booklet refers to the following models: Model – VERONA SAP Model – VERONA SED - SED TCS SPECIFICATIONS GROUPS 2 BASE 2 TCS 2 BASE TALL 2 TCS TALL 3 BASE 3 TCS 3 BASE TALL 3TCS TALL...
  • Page 2: Electrical Connection

    ENGLISH INSTALLATION ELECTRICAL CONNECTION INSTALLING THE POWER SUPPLY CABLE...
  • Page 3: Water Connection

    ENGLISH WATER CONNECTION Preliminary check 1% 0DQXDO ÀOOLQJ Hot water Steam Coffee with Mod. VERONA SAP Coffee with Mod. VERONA SED - TCS SED DISPENSER PROGRAMMING...
  • Page 4: Warranty

    ENGLISH CLEANING Filter: Drip tray and grid: Water softener: External housing: WARNINGS: APPLIANCE FAILURE WARRANTY WARNINGS INFORMATION FOR USERS...
  • Page 5 ENGLISH Instructions and connection of cup warmer and external pump Report to the service centre in case of cable damage as special equipment is required to make LEGEND repairs. D - MAIN SWITCH O - OFF 1 - PUMP AND AUTOMATION SWITCH-ON 2 - PUMP, AUTOMATION AD HEATING SWITCH-ON Q - CUP HEATER ON/OFF LIT = ON...
  • Page 6 ENGLISH Warning – correct use of rotary pumps 1-Proper Alignment of Pump and Motor 2-Quality of Water. 3-Dry operation 4-Cavitation 5-Back Feed of Hot Water 6) Wrong connections 7) Pressure strokes 8) Handling 9) Scale build up...
  • Page 7: User Interface

    ENGLISH PROGRAMMING OF THE 3DS MAESTRO DE LUX CONTROL UNIT USER INTERFACE BUTTONS BUTTON ADDITIONAL FUNCTION FUNCTION DESCRIPTION DISPLAY CONNECTION EXAMPLE OF BUTTON LAYOUT INPUTS / OUTPUTS INPUTS / OUTPUTS...
  • Page 8 ENGLISH LOW VOLTAGE ANALOG INPUTS LOW VOLTAGE OUTPUTS (low voltage) RS232 SERIAL LINE (low voltage) MICROPROCESSOR PROGRAMMING LINE (low voltage) HIGH VOLTAGE OUTPUTS (8 RELAYS) POWER SUPPLY (high voltage) CONNECTIONS SWITCHING ON THE DOSER 3D5 DE LUXE REV.X.YY OFF STATUS (DOSER OFF BUT SUPPLIED) hh:mm IDLE ON STATUS (ON) SWITCHING ON...
  • Page 9: Switching Off

    ENGLISH xxx°C hh:mm SANREMO SWITCHING OFF DISTRIBUTION COFFEE CYCLE DISTRIBUTION START DISTRIBUTION Brewing Gr:x Espresso STOP COFFEE DISTRIBUTION IN PROGRESS STOP DISTRIBUTION...
  • Page 10 ENGLISH PRE-BREWING COFFEE DISTRIBUTION IN CONTINUOUS MODE START DISTRIBUTION Continuos dose STOP DISTRIBUTION TEA CYCLE DISTRIBUTION START DISTRIBUTION Brewing Gr:x Stop tea distribution in progress STOP DISTRIBUTION...
  • Page 11 ENGLISH TEA + PUMP STEAM SPOUT DISTRIBUTION CYCLE START DISTRIBUTION Vapore DISTRIBUTION FROM STEAM WAND CYCLE (IF MANAGED BY SLAVE BOARD) Brewing Gr:x Steam STOP STEAM DISTRIBUTION IN PROGRESS LEVEL MANAGEMENT AND REGULATION MINIMUM LEVEL PROBE Boiler Empty...
  • Page 12 ENGLISH CHRONO FUNCTION Brewing Gr:x xxxxxx DISABLING TEMPERATURE DISPLAY hh:mm SANREMO DISTRIBUTION GROUPS WASHING STEAM WAND/CAPPUCCINO MAKER WASHING (IF PRESENT ON THE SLAVE BOARD)
  • Page 13: Coffee Boiler Heating

    ENGLISH LEVEL PROBE Â Â PUMP PUMP COFFEE BOILER HEATING CHARACTERISTICS REGULATING MODES WITH ON/OFF REGULATION WITH 2°C HYSTERESIS WITH PID REGULATION (DEFAULT SETTING) T°SET...
  • Page 14: Programming Coffee Doses

    ENGLISH PROGRAMMING AND READINGS PROGRAMMING COFFEE DOSES Doses setting Select within10s START DISTRIBUTION STOP DISTRIBUTION ‡ ‡ ‡ IF A COFFEE DOSE DOES NOT WORK… Solving possible problems: PROGRAMMING CONTINUOUS/3COFFEES DOSE Setting Gr.x Continuos...
  • Page 15: Programming The Clock

    ENGLISH PROGRAMMING TEA DOSES Doses setting Select within10s ‡ ‡ ‡ PROGRAMMING STEAM TEMPERATURE BY SIMULATION Doses setting Select within30s ‡ PROGRAMMING THE CLOCK Doses setting Select within30s Clock adjust Clock adjust hh.mm XXXXXXXXX...
  • Page 16 ENGLISH AUTO ON/OFF - AUTOMATIC SWITCHING ON/OFF $OORZV \RX WR GHÀQH WKH WLPHV IRU DXWRPDWLFDOO\ VZLWFKLQJ WKH GRVHU RQ DQG RII DQG WKH ZHHNO\ FORVLQJ GD\ Auto ON/OFF aaa : hh.mm Auto On/Off On : --.-- Auto On/Off Off : --.-- REST DAY Closed On xxxxxxxx...
  • Page 17: Technical Level Programming

    ENGLISH zzzzzz Gr:y xxxxx TECHNICAL LEVEL PROGRAMMING 6 BUTTON KEYBOARD 6 BUTTON KEYBOARD 5 BUTTON KEYBOARD Language xxxxxxxxx Name SANREMO blank “ & ‘ < > ¥ Service Phone xxxxxxxxxx Function Crono xxxxxxxxxx...
  • Page 18 ENGLISH Disp. Temperat. xxxxxxxxxx Keyboard type Esp Caf 2Es 2Caf 5 BUTTON KEYBOARD 6 BUTTON KEYBOARD 6 BUTTON KEYBOARD Keyboard type Esp 2Es Caf 2Caf 5 BUTTON KEYBOARD 6 BUTTON KEYBOARD 6 BUTTON KEYBOARD Doses setting xxxxxxxx Continuos xxxxxxxx Tea whit Pump Steam Boiler Gr.
  • Page 19 ENGLISH Cleaning Xxxxxxx PreBrewing xxxxxxx PreBrew. xx sec yyyyy ProbeSensivity Service Cycles xxxxx Temperature °X Disp. Temperat. xx.x y.yy zz.z...
  • Page 20: Alarm Signal

    ENGLISH 08.0 0.15 10.0 00.0 0.00 00.0 Regolazione PID x°C FillingUp T-Out Water Filter xxxxx hh:mm ALARM SIGNAL TIME OUT LEVEL IN BOILER (FILLING) Time-Out alarm Boiler FillingUp KEYBOARD GROUP 1 KEYBOARD GROUP 2 KEYBOARD GROUP 3 THE LEDS ARE FLASHING THE LEDS ARE FLASHING THE LEDS ARE FLASHING BOILER TEMPERATURE...
  • Page 21 ENGLISH Alarm Boiler temp. KEYBOARD GROUP 1 KEYBOARD GROUP 2 KEYBOARD GROUP 3 THE LEDS ARE FLASHING THE LEDS ARE FLASHING THE LEDS ARE FLASHING BOILER PROBE UNCONNECTED / INTERRUPTED T.ProbeUnconnect KEYBOARD GROUP 1 KEYBOARD GROUP 2 KEYBOARD GROUP 3 THE LEDS ARE FLASHING THE LEDS ARE FLASHING THE LEDS ARE FLASHING...
  • Page 22 ENGLISH Filter Reset MAINTENANCE ALARM AND RESET Service xxxxxxxx 7(&+1,&$/ /(9(/ 3URJUDPPLQJ Pressing buttons to switch on the system Service Reset RESET TOTAL SINGLE DOSES Coffees total Pressing buttons for 3 seconds Coffees total Total Reset PRESET DEFAULT DATA Only group 1 keyboard Hold down simultaneously when switching on Preset valori completato...
  • Page 23 ENGLISH PROGRAMMING THE PIDBULL CONTROL UNIT VERSION WITH 1 KEYBOARD SWITCHING ON (VERSION WITH 1 KEYBOARD) GROUP IDENTIFICATION (DECIMAL POINT, VERSION WITH 1 KEYBOARD) THE LIT POINT IDENTIFIES THE 1 GROUP THE LIT POINT IDENTIFIES THE 2 GROUP THE LIT POINT IDENTIFIES THE 3 GROUP OFF STATUS (VERSION WITH 1 KEYBOARD) IDLE ON STATUS (VERSION WITH 1 KEYBOARD)
  • Page 24: Temperature Offset

    ENGLISH SWITCHING OFF A SINGLE GROUP rotation rotation rotation PID THERMOREGULATION T°SET ‡ ‡ ‡ ‡ ‡ ‡ TEMPERATURE OFFSET TECHNICAL LEVEL PROGRAMMING...
  • Page 25 ENGLISH when switching on F.01 = NUMBER OF HEATING GROUPS F.02 = NUMBER OF KEYBOARDS F.03 = DEGREES CELSIUS OR DEGREES FAHRENHEIT P: = PROPORTIONAL CONSTANT OF PID THERMOREGULATION i. = INTEGRATIVE CONSTANT OF PID THERMOREGULATION d: = DERIVATIVE CONSTANT OF PID THERMOREGULATION F.04 = GROUP 1 OFFSET F.05 = GROUP 2 OFFSET F.05 = GROUP 3 OFFSET...
  • Page 26 ENGLISH ALARM SIGNAL TEMPERATURE PROBE UNCONNECTED / INTERRUPTED TEMPERATURE PROBE SHORT CIRCUITING / EXCESS TEMPERATURE PRESET DEFAULT DATA when switching on PROCEDURES IN THE EVENT OF A POWER CUT...

This manual is also suitable for:

Verona sedVerona tcs sed

Table of Contents