Width
Depth
Height
Capacity
Voltage
Heating element input
Power absorbed by cup warmer
Electric pump input
Solenoid valve input
External automatic level controller input
Automatic level controller input
Boiler design pressure
Boiler working pressure
Safety valve calibration pressure
Exchanger design pressure
Exchanger safety valve calibration pressure
Mains water pressure (max)
Coffee dispensing pressure
The weighted sound pressure level A of the coffee machine is less than 70dB.
For correct appliance operation and trouble-free maintenance, please read this booklet carefully and
comply with the instructions and rules, also referring to the diagrams given in it.
Before installing the appliance ensure that the mains voltage and power correspond to the data given in
the specifications table. Take the appliance out of the packaging and put it in its final place of installation
ensuring that it is stable and safe and that there is the necessary space for using it.
Position the appliance at a height of 1.5 m from the ground to the top cup grid.
Connect the power cable to the mains supply through a circuit breaker with suitable capacity. The
appliance must also be efficiently earthed.
N.B. CHECK THAT THE DATA ON THE RATING PLATE CORRESPOND TO YOUR MAINS
ELECTRICITY SUPPLY.
26
Model – MILANO SAP
Model – MILANO SED

SPECIFICATIONS

GROUPS
mm
mm
mm
litres
V
kW
kW
kW
kW
kW
kW
(2 Bar) MPa
(0,8-1 Bar) MPa
(1,8 Bar) MPa
(20 Bar) MPa
(12 Bar) MPa
(6 Bar) MPa
(8-9 Bar) MPa

INSTALLATION

Electrical connection

1
2
485
640
500
500
535
535
4,5
8,6
110-120~
110-120~
220-240~
220-240~
380-415~
380-415~
1,95/2,4
2,7/4,5
/
0,2
0,15
0,15
0,15
0,15
0,0135
0,0225
0,01
0,01
0,2
0,2
0,08:0,1
0,08:0,1
0,18
0,18
2
2
1,2
1,2
0,6
0,6
0,8/0,9
0,8/0,9
3
870
500
535
14
110-120~
220-240~
380-415~
5,1
0,25
0,165
0,187
0,0315
0,01
0,2
0,08:0,1
0,18
2
1,2
0,6
0,8/0,9