4. HOW TO CONTROL CHART OBJECTS
TM Reset: In the true motion mode, own ship moves until it reaches the true motion
reset borderline (set here), and then it jumps back to an opposite position on screen
based on its course. Set the limit for TM reset (in percentage). For example, "80" re-
sets the position when the own ship marker is at a location which is 80% of the range.
4.2.3

Chart Display menu

To access this menu and its pages, click [DISP], [SET] and [Chart DISP] on the
InstantAccess bar then open the [Standard], [Other] or [NtoM] page as appropriate.
The [Standard] page contains chart features defined by IMO that comprise a standard
display. You can recall the standard display at any time in a single action; click the
[STD DISP] button on the Status bar to get the standard display.
The [Other] page contains chart features for which you can control visibility and that
are not part of IMO-defined standard display.
The [NtoM] page controls the Notice to Mariners information, for both ENC and Jep-
pensen C-MAP charts.
Note: To use the Info request feature, which provides information for cursor-chosen
chart feature, the associated chart feature must be turned on from the [Standard],
[Other] or [NtoM] page.