Furuno FMD-3200 Operator's Manual page 415

Electronic chart display and information system
Hide thumbs Also See for FMD-3200:
Table of Contents

Advertisement

No.
Text
024
RS485 Communi-
cation Timeout
025
No Signal
026
Sentence Syntax
Error
027
Main Monitor COM
Timeout
028
Sub Monitor
COM Timeout
030
Sensor Adapter 1
COM Timeout
031
Sensor Adapter 2
COM Timeout
032
Sensor Adapter 3
COM Timeout
033
Sensor Adapter 4
COM Timeout
034
Sensor Adapter 5
COM Timeout
Default
Meaning
Caution
For MU-190/231: Connect-
ed to COM2. There has
been no communication
from processor unit through
RS485 for 180 seconds.
(No communication implies
incomplete sentence or
checksum error.)
Caution
For MU-190/231: Connect-
ed to COM2. There has
been no signal continuously
for 60 seconds.
Caution
For Sub monitor, connected
to COM2, value of external-
ly input sentence is out of
range defined by sentence.
Caution
Communication with MU is
interrupted. 60 seconds tim-
eout.
Caution
Communication with MU is
interrupted. 60 seconds tim-
eout.
Caution
Communication error with
No.1 sensor adapter is de-
tected. 30 seconds timeout.
No.1 sensor adapter is
turned off, or there is a prob-
lem with network.
Caution
Communication error with
No.2 sensor adapter is de-
tected. 30 seconds timeout.
No.2 sensor adapter is
turned off, or there is a prob-
lem with network.
Caution
Communication error with
No.3 sensor adapter is de-
tected. 30 seconds timeout.
No.3 sensor adapter is
turned off, or there is a prob-
lem with network.
Caution
Communication error with
No.4 sensor adapter is de-
tected. 30 seconds timeout.
No.4 sensor adapter is
turned off, or there is a prob-
lem with network.
Caution
Communication error with
No.5 sensor adapter is de-
tected. 30 seconds timeout.
No.5 sensor adapter is
turned off, or there is a prob-
lem with network.
APPENDIX 5 ALERT LIST
Remedy
Check the connection of
brightness control cable.
Check the connection of
video cable.
If the error frequently
occurs, contact FURUNO
and inform frequency of
occurrence.
Check the connection with
the monitor.
Check the connection with
the monitor.
Check the connection with
No.1 sensor adapter and
network.
Check the connection with
No.2 sensor adapter and
network.
Check the connection with
No.3 sensor adapter and
network.
Check the connection with
No.4 sensor adapter and
network.
Check the connection with
No.5 sensor adapter and
network.