Permanent Warnings For S57 Charts - Furuno FMD-3200 Operator's Manual

Electronic chart display and information system
Hide thumbs Also See for FMD-3200:
Table of Contents

Advertisement

Update Date: Date of update
Compilation Scale: The scale of the original paper chart is shown here.
Projection: Projection of current chart.
Horizontal Datum: Horizontal datum used with current chart.
Sounding Datum: Datum used to create sounding data.
Vertical Datum: Vertical datum used with current chart.
Units of Depth: Unit of depth used with current chart.
Units of Height: Unit of measurement used to measure height of objects above sea
level.
Magnetic Variation: Amount of magnetic variation. A positive value indicates a
change in an easterly direction and a negative value indicates a change in a westerly
direction.
Quality Indication: Quantitative estimate of the accuracy of chart features, given by
the chart producer.
5.1.3

Permanent warnings for S57 charts

Permanent warnings help you keep the S57 charts up-to-date and these are shown at
the bottom of the screen. Permanent warnings appear if the system detects a condi-
tion that may cause a chart to be not up-to-date.
Display date is not current
ENC: permits have expired
ENC: Product list not up to date
ENC: AIO product list not up to date
No connection to dongle
Not up to date (SSE 27): XXXXXXXX
(Chart name appears at location of Xs.)
Permit expired (SSE 25): XXXXXXXX
(Chart name appears at location of Xs.)
Note: The system can assist in keeping RENC-received charts up-to-date. For charts
that have been loaded from sources other than an RENC, the system is unable to
know the exact up-to-date situation.
Message
5. VECTOR (S57) CHARTS
Meaning, Remedy
Display date is not the current date. Set
Display date and Approved until date to the
current date.
You have an expired permit for a chart. Re-
move the chart or renew subscription for
the permit.
The product list is not up to date. Chart(s)
is older than 30 days from its publication
date. Load up-to-date chart(s).
The product list is not up to date. AIO data
is older than 30 days from its publication
date. Load up-to-date AIO data.
The dongle is not inserted or not recog-
nized. Insert the dongle to erase the mes-
sage.
At least one chart is not up to date. Load
updated material.
You have an expired permit for a chart. Re-
move the chart or renew subscription for
the permit.
5-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fmd-3300Fmd-3200-bb

Table of Contents