TCP/IP Settings of Controlled Device:
This option programs the IP parameters for display control. The static IP address set here should
match the display's static IP address. To set or view the display's address, check the display's user
manual.
Note: The switcher and the display must be on the same network for these commands to work
Note: Be sure the static IP address set for the display does not match any other device on the network
IP Mode -
Non-login: Does not require a username and password when using TCP/IP to control the
Login: Requires a username and password to control the display through TCP/IP
IP Address & Port - Set to match the display's static IP
Username & Password - Required when in login mode
Save - Saves the IP settings for accessing the controlled device
RS-232/IP Commands:
ASCII/Hex - Set which type of commands are sent to the display
On/Off/Volume+/Volume-/Mute - Enter the specific commands and feedback that will be sent/
Note: Individual commands will be found in the display's manual
End of line symbols - None, CR, LF, CR-LF, Space, STX, ETX, Null - Select the appropriate
Note: Be sure to check the display's manual for the correct symbol
Feedback - Feedback commands can be set by typing in the field or will auto fill after pressing
the test button.
Note: If the command is incorrect, you will get a red 'Timeout!' message at the top of the RS-232 field
atlona.com
display
received when using any of the control options
symbol from the drop down list. Carriage return, line feed, and carriage
return with line feed are the most commonly used symbols.