475 – AL CR Trigger Engine Stop
Cause
Alarm configuration; activated
when crash recorder triggered
by an engine shutdown
476 – AL Crash Rec. Init. Error
Cause
Alarm configuration;
Initialization error of crash
recorder.
478 – AL Comb. Alarm Yel (Plant)
Cause
Alarm configuration; Combined
alarm YELLOW from plant.
479 – AL Comb. Alarm Red (Plant)
Cause
Alarm configuration; Combined
alarm RED from plant.
480 – AL Lim Ext. Plant Bin
Cause
Alarm configuration limit value;
input signal has exceeded / not
attained limit, depending on
application engineering.
ZKP-Number: 1.8010.009
Corrective action
u Determine and rectify cause of triggering / engine shutdown.
ZKP-Number: 1.8010.007
Corrective action
u Check settings with DiaSys.
ZKP-Number: 2.8006.001
Corrective action
u Check additional messages.
ZKP-Number: 2.8006.002
Corrective action
u Check additional messages.
ZKP-Number: 2.0291.921
Corrective action
u Determine cause of limit value violation and rectify fault.