335 – AL Wiring Cylinder B5
Cause
Wiring bank 2 (solenoid valve 5)
336 – AL Wiring Cylinder B6
Cause
Wiring bank 2 (solenoid valve 6)
337 – AL Wiring Cylinder B7
Cause
Wiring bank 2 (solenoid valve 7)
338 – AL Wiring Cylinder B8
Cause
Wiring bank 2 (solenoid valve 8)
339 – AL Wiring Cylinder B9
Cause
Wiring bank 2 (solenoid valve 9)
340 – AL Wiring Cylinder B10
Cause
Wiring bank 2 (solenoid
valve 10)
341 – AL Open Load Cylinder A1
Cause
Open load bank 1 (solenoid
valve 1)
ZKP-Number: 1.8004.534
Corrective action
1. Check solenoid valve.
2. Contact Service.
ZKP-Number: 1.8004.535
Corrective action
1. Check solenoid valve.
2. Contact Service.
ZKP-Number: 1.8004.536
Corrective action
1. Check solenoid valve.
2. Contact Service.
ZKP-Number: 1.8004.537
Corrective action
1. Check solenoid valve.
2. Contact Service.
ZKP-Number: 1.8004.538
Corrective action
1. Check solenoid valve.
2. Contact Service.
ZKP-Number: 1.8004.539
Corrective action
1. Check solenoid valve.
2. Contact Service.
ZKP-Number: 1.8004.540
Corrective action
1. Check solenoid valve.
2. Contact Service.