349 – AL Open Load Cylinder A9
Cause
Open load bank 1 (solenoid
valve 9)
350 – Open Load Cylinder A10
Cause
Open load bank 1 (solenoid
valve 10)
351 – AL Open Load Cylinder B1
Cause
Open load bank 2 (solenoid
valve 1)
352 – AL Open Load Cylinder B2
Cause
Open load bank 2 (solenoid
valve 2)
353 – AL Open Load Cylinder B3
Cause
Open load bank 2 (solenoid
valve 3)
354 – AL Open Load Cylinder B4
Cause
Open load bank 2 (solenoid
valve 4)
355 – AL Open Load Cylinder B5
Cause
Open load bank 2 (solenoid
valve 5)
ZKP-Number: 1.8004.548
Corrective action
1. Check solenoid valve.
2. Contact Service.
ZKP-Number: 1.8004.549
Corrective action
1. Check solenoid valve.
2. Contact Service.
ZKP-Number: 1.8004.550
Corrective action
1. Check solenoid valve.
2. Contact Service.
ZKP-Number: 1.8004.551
Corrective action
1. Check solenoid valve.
2. Contact Service.
ZKP-Number: 1.8004.552
Corrective action
1. Check solenoid valve.
2. Contact Service.
ZKP-Number: 1.8004.553
Corrective action
1. Check solenoid valve.
2. Contact Service.
ZKP-Number: 1.8004.554
Corrective action
1. Check solenoid valve.
2. Contact Service.