Fault Messages Of Engine Governor Adec (Ecu 7) For Series 4000, Application: Oil & Gas - MTU 12 V 4000 G73 Operating Instructions Manual

Hide thumbs Also See for 12 V 4000 G73:
Table of Contents

Advertisement

6.3 Fault messages of engine governor ADEC (ECU 7) for Series
4000, application: oil & gas
003 – HI T-Fuel
Preliminary warning
Cause
Fuel temperature too high.
004 – SS T-Fuel
Main warning
Cause
Fuel temperature too high;
Engine stop.
005 – HI T-Charge Air
Preliminary warning
Cause
Charge-air temperature too high.
006 – SS T-Charge Air
Main warning
Cause
Charge-air temperature too high
Engine stop.
009 – AL L1 T-Coolant Intercooler
Cause
Charge-air coolant temperature
too high (1st limit value).
ZKP-Number: 2.0122.931
Corrective action
u Contact Service.
ZKP-Number: 2.0122.932
Corrective action
u Contact Service.
ZKP-Number: 2.0121.931
Corrective action
1. Reduce power.
2. Check intercooler.
ZKP-Number: 2.0121.932
Corrective action
1. Reduce power.
2. Check intercooler.
ZKP-Number: 2.0124.931
Corrective action
u Reduce power.
MS150029/02E 2013-03 | Troubleshooting | 43