4.7 Emergency stop

NOTICE
An emergency stop causes extreme stress to the engine plant.
Risk of overheating, damage to components!
• Initiate emergency stop only in emergency situations.
Emergency stop
Item
Emergency stop pushbutton Press EMERGENCY STOP pushbutton.
After emergency stop
Item
Switchgear cabinet, control
panel etc. (depending on
manufacturer)
Engine
Action
Engine is stopped by disconnecting the power supply to the ECU;
Emergency air shutoff flaps close (if provided);
Signalization (e.g. by horn, beacon) is activated.
Action
Press pushbutton for alarm acknowledgment.
Audible and visual signalization stops.
Manually open emergency air shutoff flaps (if provided).
Engine is ready for starting.