270 – SD Frequency Input
Cause
Sensor defective, frequency
setting.
301 – AL Timing Cylinder A1
Cause
Timing bank 1 (solenoid valve 1)
302 – AL Timing Cylinder A2
Cause
Timing bank 1 (solenoid valve 2)
303 – AL Timing Cylinder A3
Cause
Timing bank 1 (solenoid valve 3)
304 – AL Timing Cylinder A4
Cause
Timing bank 1 (solenoid valve 4)
305 – AL Timing Cylinder A5
Cause
Timing bank 1 (solenoid valve 5)
306 – AL Timing Cylinder A6
Cause
Timing bank 1 (solenoid valve 6)
62 | Troubleshooting | MS150029/02E 2013-03
ZKP-Number: 2.8006.590
Corrective action
1. Check cabling.
2. Contact Service.Check speed demand transmitter.
ZKP-Number: 1.8004.500
Corrective action
u Replace injector concerned if the fault message appears
frequently (→ Page 99).
ZKP-Number: 1.8004.501
Corrective action
u Replace injector concerned if the fault message appears
frequently (→ Page 99).
ZKP-Number: 1.8004.502
Corrective action
u Replace injector concerned if the fault message appears
frequently (→ Page 99).
ZKP-Number: 1.8004.503
Corrective action
u Replace injector concerned if the fault message appears
frequently (→ Page 99).
ZKP-Number: 1.8004.504
Corrective action
u Replace injector concerned if the fault message appears
frequently (→ Page 99).
ZKP-Number: 1.8004.505
Corrective action
u Replace injector concerned if the fault message appears
frequently (→ Page 99).