Initialize Remote Control; Check Operation; Set Aeration (If Necessary) - Valor 1800JN Installation & Owner's Manual

Dv zc gas fireplace l3 series
Table of Contents

Advertisement

QUALIFIED
INSTALLER

Initialize Remote Control

The receiver and the handset of the remote control sys-
tem must be initially synchronized before the fi rst use.
1. Insert one 9 V alkaline battery in the handset.
2. Locate the Reset button on the top side of the
receiver.
3. With a sharp object, press and hold the receiver's reset
button until you hear one short and one long beeps.
Release the reset button after the second beep.
4. Within the subsequent 20 seconds, press the (small
fl ame button (
) on the remote handset until you
hear two short beeps confi rming the synchronization
is set.
This is a one time setting only and is not required when
changing the batteries in the remote battery holder. The
remote control system is now ready to use.

Check Operation

Turn the fi replace fl ame up and down using the
remote control to confi rm that the full range of inputs
is achieved—see the remote control operation
instructions on pages 11–15.

Set Aeration (if necessary)

Light the fi re and allow the unit to warm up for 11–15
minutes to evaluate the fl ame picture. The burner is
equipped with an adjustable shutter to control primary
aeration (NG only). The shutter is factory-set to an
aeration gap which will give optimum performance for
the vast majority of installations.
In a few unusual installations, the fl ame picture may
be improved by adjusting the aeration. The need for
adjustment should be determined only by operating the
appliance with the fuel bed and window installed.
Air Shutter
Accessing air shutter
50
Installation
Remove front middle
platform support
Velcro
Appliance's
front panel
Increasing aeration will cause the fl ames to appear
more transparent and blue showing more ceramic
effects glow.
Decreasing aeration will cause the fl ames to appear
more yellow or orange showing less ceramic effects glow.
Too little aeration may result in black carbon
forming and dropping into the fi rebox.
To access the air shutter, remove the front middle
platform as indicated. The air shutter is located under
the burner as shown in the illustrations. Loosen the air
shutter screw, adjust and re-tighten.
Open
Air shutter
Close
Setting air shutter: Loosen screw to adjust and
re-tighten afterwards.
Reset
button
Battery
wall holder
connection
Injector elbow
Foam
gasket
Injector elbow bracket,
burner side