7. Pull the excess cable back through the cable clamp
and tighten the locking ring to the cable clamp.
Alternate clamp without locking ring may be used
- ensure the proper clamp is used for the type of
cable used.
8. Tighten cable clamp on outside of fi replace casing
and secure and excess wire to framing.

Set-up Gas Supply

The gas supply inlet
connection is a 3/8" NPT
male connector located
on the left hand side of
the fi rebox.
The unit is supplied with a stainless steel fl ex line to
allow the appliance to be disconnected for service. An
individual shut-off valve (not supplied) is required on
the supply line ahead of the fl ex connector.
Use only new black iron or steel pipes or copper tubing
if acceptable—check local codes. Note that in USA,
copper tubing must be internally tinned for protection
against sulfur compounds.
Unions in gas lines should be of ground joint type.
The gas supply line must be sized and installed to
provide a supply of gas suffi cient to meet the maximum
demand of the appliance without undue loss of pressure.
Installation
X
Gas line
access hole
2-1/2" (64 mm)
diam.
4 "
( 1 0
2 m
m )
Left side view
Sealant used must be resistant to the action of all gas
constituents including LP gas. Sealant should be ap-
plied lightly to male threads to ensure excess sealant
does not enter gas lines.
QUALIFIED
INSTALLER
Front
of the
appliance
3-3/4"
(95 mm)