Install Electrical Wiring (for optional
accessories)
This section provides information to install the electric
pre-wiring required for use with the 1595CFK Circulat-
ing Fan Kit.
All wiring must be done by a qualifi ed electrician in
accordance with local codes or, in the absence of
local codes, with the National Electrical Code, ANSI/
NFPA 70 or the Canadian Electrical Code, CSA C22.1.
Electrical Requirements
1595CFK—120 V, 60 Hz, less than 1 amp
General Requirements
The optional 1595CFK kit includes a three-prong
grounded plug to plug into a grounded duplex recepta-
cle installed within the fi replace enclosure by a qualifi ed
electrician.
Notes
• A fan speed control will need to be provided by the
electrician, mounted at a convenient location on the
wall, and connected to control the power supply to
the receptacle within the fi replace enclosure.
• The receptacle and box must be located as per
these instructions. Wiring within this box must have
a minimum 90°C temperature rating.
Installation
1. Thread the cable through the cable clamps and
through the hole in the lower right hand corner of
the fi replace casing. Do not tighten the clamps yet.
Note: Receptacle tabs may be "split" to render the
other receptacle inoperative.
Fireplace
Fireplace
casing
casing
38
Installation
Stud
Stud
Pull just enough cable
out front for now to
make termination easier
2. Provide a steel surface mount electrical utility box
(Iberville BC 1110 or equivalent), thread cable
through knock-out in the end of box and through the
cable clamp locking ring (if used).
3. Strip wire and terminate grounded receptacle.
"Split" receptacles to render the other receptacle
inoperative.
4. Mount receptacle into electrical box.
5. Mount steel cover to electrical box and plug in the
fan cable.
6. Position the electrical box to the base of the
fi replace with the fan cable plugged in sideways,
layed sideways.
Cable clamp
locking ring
Positioned
sideways inside
fi rebox