5.
Select Done after you have input the X and Y offsets. The printer will return to Maintenance.
Run the XY calibration a second time to be sure the values changed the offset properly.
6.
When finished, press Done until back at Idle.
As Needed Maintenance
The following maintenance items have no routine schedule but should be tended to as needed.

Chamber Light Bar

CAUTION:
Replace a chamber light bar when it burns out.
Note:
the front wall of the chamber - one to the right, the other to the left of the
chamber door.
Replace chamber light bar:
1.
Power down the printer.
2.
Locate the wiring harness leading away from the bottom of the light bar.
3.
Disconnect the light bar from the wiring harness by squeezing the wiring harness clip while
pulling down.
Remove the light bar by removing the 3 attachment screws (top, middle, bottom) - use the 7
4.
T-handle wrench supplied in the Startup Kit.
5.
Install a replacement light bar with the 3 attachment screws - do not overtighten the screws.
6.
Re-attach the wiring harness lead.
ESD:
Use proper ESD grounding techniques when handling
electronic components.
Use only a factory authorized replacement light bar.
There are two light bars in the modeling chamber. They are located on