11 Electrical checks of
main parts
11.7 Reactor (DCL)
11.7.1 Reactor (DCL) for IVX Series
This part is used for changing the alternative current to the direct current for the inverter.
RAS-(4-6)HRNM1E (400V/50Hz), RAS-(8-12)HRNM (380-415V/50Hz)
Items
Character
Rated current
Direct resistance
Permissible temperature range
11.7.2 Reactor (DCL) for ES Series
This part is used for changing the alternative current to the direct current for the inverter.
RAS-(4-6)HVRNS1E (230V/50Hz)
Items
Character
Rated current
DC Resistance
Permissible temperature range
This part is used for changing the alternative current to the direct current for the inverter.
453
SMGB0060 rev. 1- 12/2010
Specifications
1.0 mH+10% (at 1 kHz)
30 A
22.8 mΩ+20% (at 20 °C)
-20 ºC to 65 ºC
Specifications
0.59 mH±15% (at 1 kHz)
30 A
26 mΩ (at 20 °C)
-20ºC to 60ºC
11