8 Troubleshooting
8.2.3 Troubleshooting by means of the 7-segment display
Simple checking by 7-segment display
•
During auto-addressing, the following items can be checked using the outdoor unit's on-board 7-segment LED display:
1
Disconnection of power supply to the indoor unit.
2
Reverse connection of the operating line between the outdoor and indoor units.
3
Duplication of indoor unit number.
•
Outdoor Unit, Circuit Board, PCB1
1
Turn ON all Indoor Units connected to the Outdoor Unit
2
Turn ON the Outdoor Unit
3
Auto-addressing starts
Checking method by 7-segment display
Operating conditions and each part of refrigeration cycle can be checked by 7-segment and push switches (PSW) on the
PCB in the outdoor unit. During checking data, do not touch the electric parts except for the indicated switches because
220-240 V (400 V in case of RAS-(4-6)HRNM1E, RAS-(8-12)HRNM and RAS-8/10HRNSE) is applied to them. Pay attention
not to contact the tools with electrical parts. If contacted, electrical parts will be damaged.
•
To start checking, press PSW2 switch for more than three
seconds.
•
To proceed checking, press the PSW2 switch.
•
To back to the previous item, press the PSW3 switch.
•
To cancel this checking, press the PSW2 switch for more than
3 seconds
290
SMGB0060 rev. 1- 12/2010