10 Servicing
¿
Removing electrical components
Removing control PCB (PCB1) and Relay (PCB3, PCB5)
1
Remove the service cover following
2
Remove all the wiring connected to the control PCB.
3
Move the four (4) holders to the direction marked with the arrow and remove the PCB.
Removing Relay PCB (PCB3, PCB5)
1
Remove the service cover following the
2
Disconnect all the wires connected with the relay PCB (PCB3, PCB5).
3
Clamp the middle part of the spacers (4 portions for each relay PCB) with long-nose pliers and remove PCB3 and PCB5
by pulling them out toward front side.
N O T E
DO NOT touch the electrical components on the PCB. Pay attention not to bend or apply much force onto PCB
in order to avoid PCB failure.
1: Spacer
2: Middle Part of Spacer
3: PCB (1, 3, 5)
A: Enlarged View of P
B: Electrical Box (View from Top)
C: Spacer for PCB (1, 3, 5)
Removing Inverter Components and Capacitor for AC Fan Motor
1
Remove the service cover following the
2
Open the P-mounting plate by rotating 90 degrees to the left following the
see on page 423.
Check that the LED201 (red) on DIP-IPM is OFF when the P plate is opened.
D A N G E R
DO NOT touch electrical components while the LED1 (Red) is ON to avoid electrical shock. Wait until the
LED turns off.
3
Remove inverter components and capacitor for AC fan motor (CA) according to the procedure below, and the following
figures.
Removing Inverter PCB (PCB2)
1
Disconnect the wirings of connector on the PCB2 as follows.
CN2
CN206
PCN301
C
2
Disconnect the wirings of U, V and W on the transistor module (IPM).
427
SMGB0060 rev. 1- 12/2010
Removing service
cover, see on page 414.
Removing service
cover, see on page 414.
Removing service
cover, see on page 414.
1
A
1
Opening electrical box (P-Mounting
1
B
1
C
2
3
Plate),
10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents