Servicing For Ivx Series; Outdoor Unit Ras-3Hvrnme - Hitachi RAS-5HVRNM1E Service Manual

Hide thumbs Also See for RAS-5HVRNM1E:
Table of Contents

Advertisement

10 Servicing

10.2 Servicing for IVX series

10.2.1 Outdoor unit RAS-3HVRNME

¿
Removing service cover
N O T E
Remove the main parts according to the following procedures.
To reassemble perform the procedures in reverse.
To prevent contamination of the refrigerant with water or foreign particles, do not expose open to
atmosphere for long periods.
If necessary, seal pipe ends using caps or tape.
1
Remove the three (3) fixing screws.
2
Slide the service cover downward and remove it.
3
Pay attention of not falling off the service cover.
1. Service cover.
¿
Removing bottom service cover and rear cover
1
Remove five (5) screws which fix the bottom service cover. Pull and remove the bottom service cover.
2
Remove the upper cover following
3
Remove seven (7) screws which fix the rear cover (eight (8) screws for two-fan models; the inlet grill is fixed with four
(4)). Pull backward and remove the rear cover.
1
3
1. Outlet grille.
2. Rear cover.
3. Bottom service cover.
355
SMGB0060 rev. 1- 12/2010
Removing service
cover, see on page 355.
2
1. Outdoor air thermistor attachment.
2. Inlet grille.
3. Rear cover.
1
1
2
3
10