Chapter 8 Configuring Hardware and Utilities
■ Device Properties Submenu
Select [Device Properties] in the [Adapter Properties] window and press the [Enter] key to display the
submenu.
Item
Restore Defaults
MT/Sec
MB/Sec
Data Width
Scan ID
Scan LUNs > 0
Dis-connect
SCSI Timeout
Queue Tags
■ RAID Properties Submenu
Select [RAID Properties] in the [Adapter Properties] window and press the [Enter] key to display the
submenu.
Item
Array Disk?
Hot Spare
Delete Array
Add/Delete Hot Spare
228
table: Items on the Device Properties Submenu
Setting
Reads default values for the controller.
160 (Unchangeable)
Displays the maximum transfer rate.
16 (Unchangeable)
Yes (Unchangeable)
Yes (Unchangeable)
On (Unchangeable)
10
On (Unchangeable)
table: Items on the RAID Properties Submenu
Setting
• Yes
• No (Initial value)
• Yes
• No (Initial value)
Deletes the RAID configuration when the array system is configured. You can
select this only when array system is configured.
The server does not support this setting.
Description
Sets the maximum transfer rate.
Specifies the maximum data transfer width.
Sets whether or not to scan this device at startup.
Sets whether or not to scan LUN=1 and subsequent
LUNs at startup.
Sets whether or not to permit disconnection during
command execution.
Specifies the timeout period during command
execution.
Sets whether or not to support tagged command
queues.
Description
Sets whether or not to configure an array. Set to
[Yes] to configure an array system (RAID 1) using
onboard SCSI controller.
Sets whether or not to configure a hot spare.