Step 3: Confirm And Upgrade The Firmware Via The Usb Port - AMX NXD-1700VG Instruction Manual

Modero vg series wall/flush mount touch panels
Hide thumbs Also See for NXD-1700VG:
Table of Contents

Advertisement

IP Address of computer
(not needed as this is a direct
Assigning Communication Settings for a Virtual Master
FIG. 90
7.
From within this dialog enter the System number (default is 1).
8.
Click OK three times to close the open dialogs, save your settings, and return to the main NetLinx Studio application.
9.
Click the OnLine Tree tab in the Workspace window to view the devices on the Virtual System. The default System value is one.
10. Right-click on the Empty Device Tree/System entry and select Refresh System to re-populate the list. The panel will not appear
as a device below the virtual system number (in the Online Tree tab) until both the system number used in step 7 for the VNM is
entered into the Master Connection section of the System Settings page and the panel is restarted.
Step 3: Conf irm and Upgrade the Firmware Via the USB Port
Use the CC-USB Type-A to Mini-B 5-wire programming cable (FG10-5965) to provide communication between the mini-USB
Program port on the touch panel and the PC. This method of communication is used to transfer firmware KIT files and TPD4 touch
panel files.
NOTE: A mini-USB connection is only detected after it is installed onto an active panel. Connection to a previously powered panel
which then reboots, allows the PC to detect the panel and assign an appropriate USB driver.
1.
Verify this direct USB connection (Type-A on the panel to mini-USB on the panel) is configured properly using the steps
outlined in the previous two sections.
2.
With the panel already configured for USB communication and the Virtual Master setup within NetLinx Studio, its now time to
verify the panel is ready to receive files.
3.
After the Communication Verification dialog window verifies active communication between the Virtual Master and the panel,
click the OnLine Tree tab in the Workspace window (FIG. 91) to view the devices on the Virtual System. The default System
value is one.
4.
Right-click on the System entry (FIG. 91) and select Refresh System to re-populate the list. Verify the panel appears in the
OnLine Tree tab of the Workspace window. The default Modero panel value is 10001.
NetLinx Workspace window (showing panel connection via a Virtual NetLinx Master)
FIG. 91
Modero VG Series Touch Panels - Instruction Manual
USB connection)
Upgrading Modero Firmware
Showing a Master
firmware version and
device number
Showing the current Modero
panel firmware version and
device number
Shows NetLinx Studio
version number
93