Checking The Panel Statistics; Refreshing The Panel Statistics; Clearing The Panel Statistics; Connection Utility - AMX NXD-1700VG Instruction Manual

Modero vg series wall/flush mount touch panels
Hide thumbs Also See for NXD-1700VG:
Table of Contents

Advertisement

Connection Status icon:
ICSP Messages
Total
Last 15 Minutes
Blink Messages
Total
Last 15 Minutes
Ethernet Statistics
Wireless Statistics
Clear
Refresh

Checking the Panel Statistics

1.
Press the Tools button in the Protected Setup Navigation Buttons section. This opens the Tools menu.
2.
Within the Tools menu, press the Panel Statistics button. All connection statistics are contained on this page, e.g., Received,
Processed, and Dropped ICSP Messages.

Refreshing the Panel Statistics

1.
Press the Tools button in the Protected Setup Navigation Buttons section. This opens the Tools menu.
2.
Within the Tools menu, press the Panel Statistics button.
3.
Push the Refresh button.

Clearing the Panel Statistics

1.
Press the Tools button in the Protected Setup Navigation Buttons section. This opens the Tools menu.
2.
Within the Tools menu, press the Panel Statistics button.
3.
Push the Clear button.
4.
Confirm your selection.

Connection Utility

The options on the Connection Utility popup window (FIG. 128) allow you to utilize your panel as a site survey tool. While in this
page, move around your wireless network coverage area and see if there are any weak points within the spaces between your WAPs.
Connection Utility popup window
FIG. 128
Features on this page include:
Modero VG Series Touch Panels - Instruction Manual
The icon in the upper-right corner of each Setup page shows online/offline state of the panel to the master.
• Bright red - disconnected
• Bright green - connected. Blinks when a blink message is received to dark green every 5 seconds for half a
second then go back to bright green.
• Bright yellow - panel missed a blink message from the master. It will remain yellow for 3 missed blink
messages and then turn red. It will return to green when a blink message is received.
Note: a Lock appears on the icon if the panel is connected to a secured NetLinx Master.
Messages sent between the master and the touch panel; it is the protocol they use to communicate to each
other.
• Received - The total ICSP messages received by the panel.
• Processed - The total ICSP messages processed by the panel.
• Dropped - The total ICSP messages dropped by the panel.
• Received - The total ICSP messages received by the panel in the last 15 minutes.
• Processed - The total ICSP messages processed by the panel in the last 15 minutes.
• Dropped - The total ICSP messages dropped by the panel in the last 15 minutes.
The master sends this message once every 5 seconds to all connected devices.
• Received - The total Blink messages received by the panel.
• Missed - The total Blink messages missed by the panel.
• Received - The total Blink messages received by the panel in the last 15 minutes.
• Missed - The total Blink messages missed by the panel in the last 15 minutes.
The Ethernet connection statistics for the panel.
The Wireless connection statistics for the panel.
Clears all panel connection statistics.
Refreshes all panel connection statistics.
Firmware Pages and Descriptions
128

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nxd-1200vgNxt-1500vgNxt-1700vgNxd-1500vgNxt-1200vg

Table of Contents