Download Print this page

IDEAL VOGUE SYSTEM S15 Installation And Servicing page 53

Hide thumbs Also See for VOGUE SYSTEM S15:

Advertisement

60 SPARK Gene RAt o R Re Pl ACe Ment
1. Refer to Frames 45 & 46.
2. Refer to Frame 53.
3. Remove the 2 securing screws at the top of the
casing, ensuring the expansion vessel is safely
supported, and withdraw the spark generator assy.
4. Disconnect the leads from the generator.
5. Remove 2 securing screws.
6. To replace connect all wiring and then fix the
generator in position using the 2 securing screws,
ensuring the earth lead is firmly fixed under the
lower securing screw, and the expansion vessel is
correctly located.
7. Secure the spark generator assy using 2 screws in
the top of the case.
8. Check the operation of the boiler. Refer to Frames
32-35.
61 GAS Cont Rol V Al Ve Re Pl ACe Ment
1. Refer to Frames 45 & 46.
2. Refer to Frame 53.
3. Remove the gas inlet pipe. Refer to Frame 55.
4. Unplug the electrical connection.
5. Disconnect the earth lead at the rear of the gas valve.
6. Disconnect the gas service valve
7. Remove the 2 securing screws in the underside of the
boiler casing and remove the valve.
8. Remove brass injector from gas valve outlet and re-fit
into replacement valve.
9. Replace in reverse order ensuring all seals are in good
condition and the assembly is gas sound.
10. Check the operation of the boiler. Refer to Frames 32-35.
62 Conden SAte tRAP Re Pl ACe Ment
1. Refer to Frames 45 & 46.
2. Refer to Frame 53.
3. Remove the rubber condensate pipe from
the top of the trap.
4. Rotate the trap clockwise to disengage
the trap and lift clear of the outlet
connection.
5. Refit in reverse order making sure the
trap is engaged with the outlet connection
6. Refill the condensate trap.
7. Check the operation of the boiler. Refer to
Frames 32-35.
vogue system boiler -
SeRViCinG
Se RViCin G
Installation and Servicing
3
4
5
8
3
53
53

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Vogue system s18Vogue system s26Vogue system s32