int Rod UCtion
The Vogue range of boilers are wall mounted, full sequence,
automatic spark ignition, low water content, fanned flue, high
efficiency, condensing, system gas boilers.
n ote. Due to the high efficiency of the boiler a plume of water
vapour will form at the terminal during operation.
Central heating (CH) output is fully modulating with a range of:
15
3.0 to 15.0kW (10,200
18
3.6 to 18.0kW (12,300 to 61,400 Btu/h)
26
5.2 to 26.0kW (17,700 to 88,700
32
6.4 to 32.0kW (21,800 to 109,200
The boiler is supplied fully assembled with circulating pump,
pressure gauge, pressure relief valve and CH expansion vessel.
Variable CH controls are fitted on the user control.
The boiler includes as standard:
-
Automatic bypass
-
Boiler frost protection
-
Daily pump exercise.
The boiler casing is of white painted mild steel with a white
polymer front panel.
The boiler temperature controls are located behind the lower
panel on the front of the boiler.
The heat exchanger is manufactured from stainless steel.
The boiler is suitable for connection to fully pumped, sealed
heating systems ONLY. Adequate arrangements for completely
draining the system by provision of drain cocks MUST be provided
in the installation pipework.
The standard configuration of pipework from the boiler is routed
downwards.
o Pe RAtion
When there is a demand for CH, the heating system is supplied at
the selected temperature of between 30
The boiler features a comprehensive diagnostic system which
gives detailed information on the boiler status when operating,
and performance of key components to aid commissioning and
fault finding.
8
to 51,200 Btu/h)
Btu/h)
Btu/h)
o
C and 80
o
C.
GeneRAl
SAfe H Andlin G
This boiler may require 2 or more operatives to move it to its
installation site, remove it from its packaging base and during
movement into its installation location. Manoeuvring the boiler
may include the use of a sack truck and involve lifting, pushing and
pulling.
Caution should be exercised during these operations.
Operatives should be knowledgeable in handling techniques when
performing these tasks and the following precautions should be
considered:
Grip the boiler at the base.
Be physically capable.
Use personal protective equipment as appropriate, e.g. gloves,
safety footwear.
During all manoeuvres and handling actions, every attempt should
be made to ensure the following unless unavoidable and/or the
weight is light.
Keep back straight.
Avoid twisting at the waist.
Avoid upper body/top heavy bending.
Always grip with the palm of the hand.
Use designated hand holds.
Keep load as close to the body as possible.
Always use assistance if required.