26 oP tion Al Sy Ste M Cont Rol S Kit S
Ideal offer 2 kits as follows:-
(see individual kits for installation instructions)
System Boiler Electronic Timer (7 day): 7 day electronic timer fits into the control box of the boiler. This can be fitted in
conjunction with a room thermostat and a cylinder thermostat. Features English language installation help messages.
Weather Compensation Kit: allows outside temperature sensing.
27 inte Rn Al Wi Rin G
The Ideal Vogue System boiler comes pre-fitted with a link wire between the Room Thermostat/Timer connections on the
terminal strip. This creates a permanent call for heat and must be removed when adding a Room Thermostat/Timer.
To add wired external Cylinder Thermostats, Room
Thermostats, Timers or Programmers proceed as follows:-
1. Isolate the mains supply to the boiler.
2. Remove the front panel (refer to Frame 8).
3. Swing the control box down into the servicing position (refer
to Frame 46).
4. Route incoming cables through the grommets in the
bottom panel (note: grommets are 'blind' and will require
puncturing) and secure using clamps and screws provided
in the hardware pack.
30
inStAllAtion
5. Remove terminal block cover.
6. Connect wires to terminal block.
7. Re-assemble in reverse order.
vogue system boiler -