39 Men U oP e RAtio n
St Ate of
oU t PUt S
To view the current status of the Pump, Fan, Spark Generator
and Gas Valve press ENTER and the following screen will be
displayed.
MENU
Vent System
Maximum Flow Temperature
Outside Sensor Slope
Fault Help
Press "-" until the following screen is displayed.
MENU
State of Inputs
State of Outputs
Service Mode Minimum Rate
Service Mode Maximum Rate
Press ENTER and a screen similar to the following will be
displayed.
State of Outputs
Pump:
On @ 50%
Fan (Target 3000rpm):
3000rpm
Spark Generator:
Off
Gas Valve:
On
Press "+" and "-" to view the full list.
Press Ex IT twice to return to normal operation.
Se RViCe Mode Mini MUM RAte
This feature will run the burner at minimum rate. Note that a
CH demand has to already be present for the feature to be
active. To activate the feature press ENTER and the following
screen will be displayed.
MENU
Vent System
Maximum Flow Temperature
Outside Sensor Slope
Fault Help
Press "-" until the following screen is displayed.
MENU
State of Outputs
Service Mode Minimum Rate
Service Mode Maximum Rate
Show Efficiency Level
Press ENTER and the following screen will be displayed.
Service Mode
Minimum Rate
Fan Target 2000rpm
Fan Actual 1950rpm
Press Ex IT twice to return to normal operation.
vogue system boiler -
inStAllAtion
Enter
Exit
Enter
Exit
Exit
Enter
Exit
Enter
Exit
Exit
Installation and Servicing
Se RViCe Mode M Axi MUM RAte
This feature will run the burner at maximum rate. Note that
a CH demand has to already be present for the feature to be
active. Gas rate will reduce as flow temperature approached
o
80
C. To activate the feature press ENTER and the following
screen will be displayed.
MENU
Vent System
Maximum Flow Temperature
Outside Sensor Slope
Fault Help
Press "-" until the following screen is displayed.
MENU
Service Mode Minimum Rate
Service Mode Maximum Rate
Show Efficiency Level
System Frost Protection
Press ENTER and the following screen will be displayed.
Service Mode
Maximum Rate
Fan Target 5000rpm
Fan Actual 4950rpm
Press Ex IT twice to return to normal operation.
e ffi Cien Cy l e Vel
To view the efficiency level of the boiler press ENTER and the
following screen will be displayed.
MENU
Vent System
Maximum Flow Temperature
Outside Sensor Slope
Fault Help
Press "-" until the following screen is displayed.
MENU
Service Mode Maximum Rate
Show Efficiency Level
System Frost Protection
Reset Service Time
Press ENTER and a screen similar to following will be
displayed.
Efficiency Level
1346
29260
Hours
Hours
High
Super
Efficiency
Efficiency
Press Ex IT twice to return to normal operation.
Enter
Exit
Enter
Exit
Exit
Enter
Exit
Enter
Exit
Exit
41

Hide quick links:

Advertisement

loading