t able 1 - General d ata
Vogue
Gas supply
Gas Supply Connection
Injector Size
Flow Connection
Return Connection
Flue Terminal Diameter
Average Flue Temp-Mass Flow Rate
Maximum Working Pressure (Sealed Systems)
Electrical Supply
Power Consumption
Fuse Rating
Water content
Packaged Weight
Maximum Installation Weight
Boiler Casing Size
Heat Exchanger Weight without Burner
t able 2 - Performance d ata - Central Heating
Boiler Input :
Boiler Input 'Q'
Nett CV
Gross CV
Gas Consumption
Boiler Output :
Non Condensing
70
o
C Mean Water temp.
Condensing
o
40
C Mean Water temp.
Seasonal efficiency* SEDBUK 2005
Seasonal efficiency* SEDBUK 2009
NOx Classification
* The value is used in the UK Government's Standard Assessment Procedure (SAP) for energy rating of dwellings. The test data from
which it has been calculated have been certified by a notified body.
n ote. Gas consumption is calculated using a
calorific value of 38.7 MJ/m
or 34.9 MJ/m
(935 Btu/ft
) nett
3
3
To obtain the gas consumption at a different
calorific value:
a. For l/s - divide the gross heat input (kW) by
the gross C.V. of the gas (MJ/m
/h - divide the gross heat input (Btu/h)
b. For ft
3
by the gross C.V. of the gas (Btu/ft
/h - multiply l/s by 3.6
3
c. For m
6
Central Heating
Height
Width
Depth
Max.
15
18
26
kW
15.1
18.1
26.1
(Btu/h)
51,500 61,800 89,100 109,500 10,200
kW
16.8
20.1
29.0
(Btu/h)
57,200 68,500 98,800 121,600 11,400
m
3
/h
1.559
1.869
2.695
(ft
3
/h)
55.1
66.0
95.2
kW
15.0
18.0
26.0
(Btu/h)
51,200 61,400 88,700 109,200 10,200
kW
16.2
19.3
27.9
(Btu/h)
55,100 65,900 95,300 117,200 11,000
91
91.1
91.1
88.9
89.3
89.3
(1038 Btu/ft
3
3
) gross
3
)
3
)
GeneRAl
15
(mm)
3.40
Central Heating
Central Heating
mm (in)
ºC (g/s)
72ºC (6 g/s)
2
bar (lb/in
)
W
83
litre (gal)
1.1 (0.24)
kg (lb)
37.7 (83)
kg (lb)
31.9 (70)
mm (in)
mm (in)
mm (in)
KG
6.0
Min.
32
15
18
32.1
3.0
3.6
12,300 17,700 21,800
35.6
3.3
4.0
13,600 19,700 24,200
3.314
0.310
0.372
117.1
11.0
13.1
32.0
3.0
3.6
12,300 17,700 21,800
34.3
3.2
3.9
13,100 19,000 23,400
91.1
n/a
89.3
n/a
Class 5
Key to symbols
Gb =
United Kingdom
PMS = Maximum operating pressure of water
C
C
C
* = A room sealed appliance designed for connection via ducts to a
13
33
53
horizontal or vertical terminal, which admits fresh air to the burner
and discharges the products of combustion to the outside through
orifices which, in this case, are concentric. The fan is up stream of
the combustion chamber. (*Note. C
balconly flue kits only.)
i
= An appliance designed for use on 2nd Family gas, Group H only.
2H
vogue system boiler -
18
2H - G20 - 20mbar
22mm copper compression
3.35
22mm copper compression
22mm copper compression
100 (4)
67ºC (8 g/s)
70ºC (11 g/s) 70º (14 g/s)
2.5 (36.3)
230 V ~ 50 Hz.
92
External : 3A
Internal
: 4A Time Delay
1.5 (0.33)
1.8 (0.41)
38.0 (84)
40.9 (90)
33.1 (73)
34.4 (76)
740 (29.1)
445 (17.5)
330 (13)
7.3
26
32
5.2
6.4
5.8
7.1
0.537
0.661
19.0
23.3
5.2
6.4
5.6
6.8
ie = Ireland
(Countries of destination)
covers optional high level and
53
Installation and Servicing
26
32
4.30
4.80
102
117
2.2 (0.48)
41.1 (91)
35.9 (79)
8.2
9.5

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Vogue system s18Vogue system s26Vogue system s32