49 bUR ne R Re Mo VAl And Cle Anin G
1. Remove Fan and Venturi Assembly, Refer to Frame 51.
2. Remove the ignition, detection and earth leads.
3. Remove the 2 clips securing the gas inlet pipe and remove the
pipe.
4. Remove the fan leads.
5. Remove the 4 securing nuts from the heat exchanger.
6. Remove the assembly from the heat exchanger.
7. Brush off any deposits with a SOFT brush
8a. Inspect the burner door sealing gaskets and insulation for signs of
damage. Replace as necessary.
Replacement of burner door sealing gasket
8b. Remove the silicon seal from around the burner door location
groove.
9. Re-new the seal and replace in reverse order.
50 CLEANING THE CONDENSATE TRAP / SIPHON
1. Remove the rubber condensate pipe from the
top of the trap.
2. Rotate the trap clockwise to disengage the trap
and lift clear of the outlet connection.
3. Flush out any debris under running water
4. Refit in reverse order making sure the trap is
engaged with the outlet connection.
5. Fill the trap with water before operating the
boiler.
48
SeRViCinG
vogue system boiler -
7
8
1
Installation and Servicing

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Vogue system s18Vogue system s26Vogue system s32