Honeywell TH8320R1003 Vision Pro 8000 Product Data page 66

Hide thumbs Also See for TH8320R1003 Vision Pro 8000:
Table of Contents

Advertisement

®
VISIONPRO
8000 WITH REDLINK™
2. Select Auto.
Humidification
Off
3. Touch
or
to select humidity level.
4. Touch Done to save your settings. Touch Cancel to
ignore changes.
5. If frost or condensation appears on the windows, press
MENU, scroll down and select Window Protection.
6. Window Protection is set on a scale from 1–10. A setting
of 1 represents poorly insulated windows and a setting of
10 represents well insulated windows. A lower number
automatically reduces the humidity to help prevent frost
or condensation on your windows. Use a higher number
if indoor air seems too dry. To prevent frost/condensation
on your windows during cold outdoor temperatures,
poorly insulated windows require a lower Window Pro-
tection setting, which will limit how much your humidifier
can run.
7. After you set the Window Protection setting, check for
frost/condensation on your windows in the morning. If
frost/condensation is present, adjust the Window Protec-
tion setting to the next lowest number and check for frost/
condensation on your windows the next morning. Con-
tinue to adjust the Window Protection setting to a lower
number until frost/condensation is no longer present.
NOTE: Window Protection is available only if an outdoor
air sensor is installed.
NOTE: The thermostat controls humidification and dehu-
midification as needed to maintain the desired
humidity level. Depending on how your thermo-
stat was installed, the thermostat may maintain a
15% separation between humidification and dehu-
midification settings.
68-0312—01
Auto
MCR34129
Fig. 117.
Fig. 118.
Adjusting Dehumidification Settings:
Residential Use
This feature can control a dehumidifier or use your air
conditioner to reduce humidity.
1. Touch MENU and select Dehumidification.
Dehumidification
Equipment Status
2. Select Auto.
Dehumidification
3. Touch
or
to select humidity level.
4. Touch Done to save your settings. Touch Cancel to
ignore changes.
NOTE: If your air conditioner is used to control humidity,
the temperature may drop up to 3° F below your
temperature setting until humidity reaches the
desired level.
66
MCR34100
Fig. 119.
MCR34130
Fig. 120.
Off
Auto
MCR34131
Fig. 121.