VISIONPRO
8000 WITH REDLINK™
ISU
Installer Setup
Number
Name
604
Remote Setback
50° F to 70° F
Heat Setpoint
605
Drain Pan Alert
None
S1
S2
S3
S4
606
Drain Pan Alert is
Normally Open
[See Settings]
Normally Closed
607
Dirty Filter Alert
None
S1
S2
S3
S4
608
Dirty Filtr Alert is
Normally Open
[See Settings]
Normally Closed
609
Water Leak Alert
None
S1
S2
S3
S4
68-0312—01
Table 2. Installer Setup (ISU) Table. (Continued)
Settings
Default
64° F
None
Normally Open Both
None
Normally Open Both
None
44
Residential,
Commercial
Requires
or Both
EIM
Commercial
Yes
Remote Setback requires an EIM (Equipment
Interface Module).
During occupied periods, the occupancy
sensor tells the thermostat to go to setback
settings when no one is in the room. If
someone is in the room, then it follows the
settings of the occupied period. The
occupancy sensor is ignored during
unoccupied periods.
If the thermostat is setup for non-
programmable, the occupancy sensor tells the
thermostat to go to setback settings when no
one is in the room. If someone is in the room,
then it follows the settings set by the user.
Both
Yes
Dry Contact Alerts require an Equipment
Interface Module.
Select the terminals wired to the Full Drain
Pan Dry Contact Device.
Yes
Dry Contact Alerts require an EIM (Equipment
Interface Module).
Choose an option appropriate for the type of
device installed.
Normally Open: The Dry Contact device is
normally open and will close when the device
detects the drain pan is full.
Normally Closed: The Dry Contact device is
normally closed and will open when the device
detects the drain pan is full.
Both
Yes
Dry Contact Alerts require an Equipment
Interface Module.
Select the terminals wired to the Dirty Filter
Dry Contact Device.
Yes
Dry Contact Alerts require an EIM (Equipment
Interface Module).
Choose an option appropriate for the type of
device installed:
Normally Open: The Dry Contact device is
normally open and will close when the device
detects a dirty filter.
Normally Closed: The Dry Contact device is
normally closed and will open when the device
detects a dirty filter.
Both
Yes
Dry Contact Alerts require an Equipment
Interface Module.
Select the terminals wired to the Water Leak
Dry Contact Device (wet switch).