Honeywell TH8320R1003 Vision Pro 8000 Product Data page 127

Hide thumbs Also See for TH8320R1003 Vision Pro 8000:
Table of Contents

Advertisement

Wood stove with heat pump and backup electric strips. (For applications in which the thermostat only needs to run the blower fan
when stove is hot).
1 Select Geothermal Radiant Heat at ISU 201. Connect Fan to U1, U2, or U3 as shown in the wiring diagram.
2 "U" terminals are normally open dry contacts when set up for geothermal radiant heat.
3 L/A terminal sends continuous output when thermostat is set to EM HEAT mode except when set up for Economizer or TOD. See
"Economizer Module Wiring Diagrams" beginning on page 131.
4 Y2 used with heat pumps that have 2 compressor stages.
NOTE: In Fig. , the thermostat will energize only the fan with a call for stage 1 heat. If the wood stove is hot, heat comes
from the fan coil. If the wood stove is cold, only the fan runs. The thermostat will upstage to the heat pump and
backup heat as needed to maintain the temperature.
THERMOSTAT/EIM
TO THERMOSTAT
AIR HANDLER
HEAT PUMP
O/B
AUX1
AUX2
L/A
4
1
2
127
VISIONPRO
HEAT PUMP
O
O
W
Y
Y2
4
Y
R
Y2
C
G
R
C
M31487
®
8000 WITH REDLINK™
68-0312—01

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Th8321r1001 vision pro 8000Th8110r1008 vision pro 8000