VISIONPRO
8000 WITH REDLINK™
ISU
Installer Setup
Number
Name
1014
Vent During Hum
Yes
or Dehum Calls
No
1016
Vent On High
Off
Indoor Humidity
On
1017
Ventilator Core
Off
Reminder
3, 6, 9, 12 Calendar Months
1017
Ventilator Filter
Off
Reminder
3, 6, 9, 12 Calendar Months
1100
Number of UV
0, 1, 2
Devices
1105
UV Bulb 1
Off, 6, 12, 24 Calendar Months
Reminder
Note: "1" is not
displayed if there
is only 1 UV Bulb
1105
UV Bulb 2
Off, 6, 12, 24 Calendar Months
Reminder
1200
Custom
View / Edit Custom Reminders
Reminders
Add Custom Reminders
28
Backlighting
On Demand
Continuous
1400
Clock Format
12 hour
24 hour
1401
Daylight Saving
Off
Time
On
68-0312—01
Table 2. Installer Setup (ISU) Table. (Continued)
Settings
Default
Yes
On
Off
Off
0
Off
Off
None
On Demand
12
On
54
Residential,
Commercial
Requires
or Both
EIM
Both
No
This feature is used to help reach the user's
desired humidity level by not allowing the
ventilation equipment to run during a call for
humidification or dehumidification.
Yes: Ventilation is allowed to run during a call
for humidification or dehumidification.
No: Ventilation is NOT allowed to run during a
call for humidification or dehumidification.
Both
No
This ISU is only displayed when ISU 1000
Ventilation Type is set to ERV / HRV.
Off: The humidity level has no effect on
ventilation.
On: The thermostat removes excess humidity
by turning on the ventilator when the indoor
humidity rises 10% above the user's
humidification setting. The thermostat must
be in the heat mode to ventilate on high
humidity.
Both
No
Ventilator Core Cleaning Reminder
Both
No
Ventilator Filter Cleaning Reminder
Both
No
Press the up/down arrows to select the
number of UV devices installed in the system.
Some systems may have two UV devices, one
for the A-Coil and another for Air Treatment. A
replacement reminder can be setup for each
one. Select 0 if no UV devices are installed.
Both
No
UV Bulb 1 Replacement Reminder
Both
No
UV Bulb 2 Replacement Reminder
Both
No
See "Customizable Reminders" beginning on
page 95.
Both
No
Select Continuous or On Demand
backlighting. Select Continuous backlighting if
you would like the backlight to be on all the
time (C wire is required for Continuous
backlighting).
Select On Demand backlighting if you would
like the backlight to only turn on after a key
press. After you complete your changes, the
screen stays lit for 16 seconds if the
thermostat is battery powered only or it stays
lit for 45 seconds if the thermostat is system
powered (C wire).
Both
No
Both
No
Set to Off in areas that do not follow Daylight
Saving Time.
Notes