5. Select the system mode(s) to allow dehumidification.
See Fig. 219.
NOTE: Heat includes Heat, Emergency Heat and Auto.
If the system is in Auto mode, the thermostat
will allow dehumidification if the last call was for
heat.
Cool includes Cool and Auto. If the system is in
Auto mode, the thermostat will allow dehumidifi-
cation if the last call was for cool.
Fig. 219.
6. Set Dehumidifier Fan Control settings. See Fig. 220.
• Tstat Controls Fan
Thermostat turns on the dehumidifier and the fan
when dehumidification is needed.
• Equip Controls Fan
Thermostat turns on the dehumidifier when
dehumidification is needed. The fan is controlled by
the equipment.
Fig. 220.
7. Set the desired lockout option. See Fig. 221.
®
VISIONPRO
8000 WITH REDLINK™
Fig. 221.
NOTE: ISU 1014 gives the option to lockout ventilation
on calls for dehumidification. This helps main-
tain the desired humidity level.
Dehumidification Away Mode
Dehumidification Away Mode for a commercial application is
identical to Dehumidification Away Mode for a residential
application. See “Dehumidification Away Mode” on page 84
and “Set up Dehumidification Away Mode” beginning on
page 85.

Control Dehumidification Level

1. Touch MENU and select Dehumidification.
MCR34100
Fig. 222.
Dehumidification
Equipment Status
MCR34130
Fig. 223.
Page 89