or dehumidification. The thermostat will indicate whether
this meets or may not meet the ASHRAE 62.2 Standard
or the Percent On Time setting. See Fig. 236.
NOTE: ISU 1014 Lockout Ventilation on Humidification
or Dehumidification Calls is not an option when
you select ASHRAE is Priority at ISU 1012.
11. Select whether to Ventilate on High Indoor Humidity. See
"Ventilate on High Indoor Humidity (ISU 1016)" on
page 91 for more information. See Fig. 237.
Control Ventilation Level
1. Touch MENU, and select Ventilation.
Ventilation
Equipment Status
68-0312—01
Fig. 236.
Fig. 237.
MCR34100
Fig. 238.
MCR34132
Fig. 239.
2. Select Mode, Temporary Boost, or Lockout, then select
appropriate options.
Temporary Boost
3. Touch Done to save your settings. Touch Cancel to
ignore changes.
Ventilation Options
Mode:
Auto: Ventilation runs as programmed by the installer.
Off: Ventilation remains off unless turned on using the
timer.
On: Ventilation is always on.
Ventilation Mode
Off
Temporary Boost: Touch
ventilation temporarily. To turn it off, set it to zero.
Run Ventilation For
60 minutes
Lockout: Touch
or
Select Yes to prevent ventilation from running during the Sleep
or Unoccupied (commercial) program periods or when outdoor
conditions exceed values set by the installer.
94
Mode
MCR34133
Fig. 240.
MCR34134
Fig. 241.
Auto
On
MCR34135
Fig. 242.
or
to select how long to run
MCR34136
Fig. 243.
to select Yes or No, then touch Next.