8.6 #SP-028 Optional Fan Kit (SP-41-MV Only)

WARNING - Electrical Grounding Instructions: This kit is
equipped with a three-prong (grounding) plug for your
protection against shock hazard and should be plugged
directly into a properly grounded three-prong receptacle.
Do not cut or remove the grounding prong from this plug.
WANRING: Installation of this fan kit should be done by a
qualified installer. Verify household breaker is shut off
prior to working on any electrical lines.
NOTE: It is easier to install the fan kit before connecting
the gas line to the control board.
This appliance, when installed, must be electrically
grounded in accordance with local codes, or in the
absence of local codes, with the National Electrical
Code, ANSI/NFPA 70, or the Canadian Electrical Code,
CSA C22.1.
Code-approved line voltage wiring, 14 gauge or
better, must be used when wiring this assembly. Refer
to your local electrical codes for specific require-
ments.
A pre-installed electrical box is included with the ap-
pliance, along with a receptacle/box cover assembly
in the fireplace components packet.
If installing this optional fan kit after appliance instal-
lation, remove the control board to access the control
compartment and follow instructions below. Refer to
8.3 Control Board Removal and Installation.
This kit includes:
(1) fan assembly
(1) temperature control switch with magnet attached
(2) Phillips head screws (black)
(1) speed control box with cord
Instructions:

Before unit installation, remove the back access panel
(4) screws.

With the motor end facing to the right, slide the fan
underneath the firebox. The fan assembly has mag-
netic tape located on the bottom and does not re-
quire mounting.

Mount the speed control box onto the lower right
side frame. Align the slots in the speed control box to
the holes in bracket. Secure with (2) black Philips
head screws (included).

Place the temperature control switch (magnet
attached) onto the firebox floor on the right.

Plug fan cord into the speed control assembly.

Plug the speed control box cord into the electrical box
receptacle.

Reinstall all components previously removed.

Turn speed control counter-clockwise until it 'clicks'.
This is the OFF position. Turn speed control ON by
turning knob clockwise past the 'click' -this is the
highest setting.
Hussong Mfg. Co, Inc.
SP-41, PFS Report No. 19-561
Figure 8.6 - Fan Kit Installation Access Cover
Figure 8.7 - Speed Control Location
47
Rev. 9 - November 2023