24) Device does not perform initial setup
Symptom : Factory clear or memory clear is performed. Device does not perform initial setup after rebooting.
Firmware version with problem
-
UI : V5.08.10.04_20120605.19 or earlier
-
Main F/W: V11.11.06.02 06-29-2012 or earlier
Cause : S/W defect
Troubleshooting
1) Turn off the device.
2) Open side cover.
3) Turn on the device as Power Key of UI is pressed.
4) Complete System Recovery (HDD format) and reboot the device.