4. Troubleshooting
ii) Turn the machine off and remove the rear cover. Unplug and reconnect the LSU cable on main board.
Check that the LSU motor make a sound after turning the machine on.
iii) If the LSU cable(JC39-01688A) is defective, replace it. Check that the LSU motor make a sound after
turning the machine on.
iv) If the problem persists, replace the LSU(JC97-04010A).
4-197
Copyright© 1995-2013 SAMSUNG. All rights reserved.