Samsung CLX-9201 Service Manual page 271

A3 color copier
Hide thumbs Also See for CLX-9201:
Table of Contents

Advertisement

► Error Code
A3–3310
A3–3311
A3–3312
A3–3410
A3–3411
A3–3412
► Error message
Sensor Failure: #A3-3310. Turn off then on. Call for service if the problem persists
Sensor Failure: #A3-3311. Turn off then on. Call for service if the problem persists
Sensor Failure: #A3-3312. Turn off then on. Call for service if the problem persists
Sensor Failure: #A3-3410. Turn off then on. Call for service if the problem persists
Sensor Failure: #A3-3411. Turn off then on. Call for service if the problem persists
Sensor Failure: #A3-3412. Turn off then on. Call for service if the problem persists
► Symptom
Outer temperature/humidity sensor is defective.
► Troubleshooting method
A3–3310 / A3–3311 / A3–3312 : Temperature function is abnormal.
A3–3410 / A3–3411 / A3–3412 : Humidity function is abnormal.
1) Enter SVC mode. Execute sensor test to check the sensor operation. (Diagnostics > Engine Diagnostics > Engine
Test Routines > 109-0013 Outer Temperature )
2) Remove the left cover.
(Refer to 3.3.4 Temperature Sensor)
Measure the resistance value of the connector at both ends.
If the value is not in 47.5KΩ ~ 52.5KΩ (@ 25 ℃), replace the sensor(JC93-00486A).
3) If the harness and sensor are normal, replace the main board (JC92-02429A).
Copyright© 1995-2013 SAMSUNG. All rights reserved.