Diagnostics > Image Management > Auto Tone Adjustment Activation > Full
Purpose
Operation Procedure
Verification
Specification
Reference
Copyright© 1995-2013 SAMSUNG. All rights reserved.
To correct image quality when any OPC drum is replaced or the life of the OPC drum is changed.
replacing any OPC drum or density of the image is poor. And this function will be performed when
temperature and/or humidity in the room changes suddenly.
Change execution condition(s) of Normal TRC Control.
On : Full TRC Control Enable
Off : Full TRC Control Disenable
Print out a test job and make sure the image quality has recovered.
N/A
Refer to 4.6.6 Light Image