Read-Out Mode (X00) - REMEHA Quinta 30 Technical Information

High-effi ciency condensing boiler
Table of Contents

Advertisement

6.7 Read-out mode (X00)

To check boiler set points and values.
Using the 'm'-key, press repeatedly until !(flashing dot) appears in the 'code'-display.
Then select the required code @, # or $ etc. using the 's'-key.
Code
Description
Actual flow temperature
!
Actual return temperature
@
Actual DHW temperature (only with sensor)
#
Actual outdoor temperature (with Chronotherm sensor) 05
$
n/a
%
Flow temperature (set point)
^
Actual heat demand status
&
Calculated HTG cut-in temperature
*
Actual flow temperature rise [0.1 °C/sec]
(
n/a
A
Table 10
Read-out mode user level
6.8 Fan speed mode (<00)
Using the 'm' -key, press repeatedly until 'code'-display shows alternate flashing half
digits.
The value in the t-display shows the actual fan speed using two alternate double
digits as table:
Code
,
>
Table 11
Fan speed mode service level
6.9 Failure mode (x00)
To check the latest failure with the accompanying operating codes and relevant tempe-
ratures.
Using the 'm' -key, press repeatedly until 1 (flashing digit) appears in the 'code'-dis-
play.
Then select the required code 2, 3 or 4 etc. using the 's'-key and read off the
relevant value.
Description
Fan speed
Fan speed
28
Remeha Quinta 30
Read-out
(example)
80
70
58
3&
80
1x = demand;
0x = no demand
67
02
Example 5250 r/m
52 hundreds
50 units14