REMEHA Quinta 30 Technical Information page 30

High-effi ciency condensing boiler
Table of Contents

Advertisement

Fig. 05 Minimum clearances around the
boiler
05.W3H.79.00065
7.3 Flue gas discharge and air supply
7.3.1 General
The Remeha Quinta 30 is suitable for conventional room ventilated or room sealed
operation. Specify at the time of ordering if the boiler is to be installed for twin pipe
room sealed operation. In that case, the boiler will be supplied with an adaptor plate
(concentric to twin pipe).
Before installing flue system, remove the transit cover plate.
Fig. 06 Top view Remeha Quinta (standard concentric version with optional twin pipe
adaptor shown right)
05. W3H.79.00077 + 00.W3H.79.00045
The following minimum clearances are
LET OP : VOOR DE VERSCHILLENDE
required:
UITVOERINGEN GELDT:
- Front: 600 mm
Concentrische LT & RGA
- Sides: 25 mm
Excentrische LT & RGA
Uitvoering
- Bottom: 250 mm
- Top: 400 mm.
30
Remeha Quinta 30
Dld
05.W3H.79.00065
Ned
00.W3H.79.00040
Zie laag
Verwijzend tek.nr.
Zie ook tabel